click for a larger view
|
The efficient SL-31 provides lower heat input and airflow than other commercial dryers without sacrificing drying speed. The unique space-saving cabinet design of this 30-lb capacity unit enables it to be stacked one on top of the other to maximize floor space. |
Drying Performance: The SL-31 achieves outstanding drying performance. The unique design with 100% axial airflow allows for optimal drying performance in gas, steam, or electrically heated dryers. Dramatic utility savings are realized without sacrificing dry times.
Easy To Use Microprocessor Controls: Solaris dryers are equipped with a state-of-the-art computer board that constantly monitors the drying cycle from beginning to end. The Residual Moisture Control auto-dry feature provides pinpoint accuracy, preventing over-drying, which saves time and energy. The multi-lingual micro is also self-diagnostic, which means problems are quickly identified and downtime is reduced. On-premise units feature S.A.F.E., sensor activated fire extinguishing system, which virtually eliminates the risk of fires due to spontaneous combustion.
Durability: The SL-31 features a rugged four-wheel support system that parallels the design of larger industrial dryers. Stainless steel tumblers, door hinges and lint screens are impervious to corrosion while heavy-duty doors feature a heat-saving double glass design. Components are 98% front accessible for ease of service.
- Compact size
- Stainless steel tumbler
- Four-wheel drum support
- Option to stack one dryer on top of another
- Single-phase reversing available
- Front serviceable, inclusive for tumbler and belt
- S.A.F.E. feature available as an option
|
Unit
of Measure |
Metric
Unit |
Maximum Capacity
(Dry Weight) |
30 lb
|
13.61 kg
|
Tumbler Diameter |
30"
|
76.20 cm
|
Tumbler Depth |
27"
|
68.58 cm
|
Tumbler Volume |
11.04 cu ft
|
312.62 L
|
Tumbler/Drive Motor |
1/4 hp |
0.19 kW
|
Blower/Fan Motor |
1/2 hp
|
0.37 kW
|
|
Cabinet Width
|
31-1/8"
|
79.06 cm |
|
Cabinet Height
|
44-25/32"
|
113.75 cm |
|
Cabinet Depth (Gas & Electric)
|
34-1/2"
|
87.63 cm |
|
Cabinet Depth (Steam)
|
36-29/32"
|
93.73 cm |
Door Opening (Diameter) |
19-3/8" |
49.21 cm |
Door Sill Height |
14-7/8"
|
37.78 cm
|
Water Connection |
3/4"-11.5 NH (North America)
3/4" B.S.P.T. (Outside North America) |
Dryers Per 20'/40' Container |
12 / 28
|
Dryers Per 48'/53' Truck |
34 / 38
|
Gas |
Voltage Available |
120-240v 1ø 2w 50/60 Hz |
Approximate Net Weight |
285 lb
|
129.27 kg
|
Approximate Shipping Weight |
310 lb
|
140.61 kg
|
Airflow (60 Hz) |
360 cfm
|
10.19 cmm
|
Airflow (50 Hz) |
300 cfm
|
8.49 cmm
|
Heat Input |
55,000 Btu/hr
|
13,860 kcal/hr
|
Exhaust Connection (Diameter) |
6"
|
15.24 cm
|
Compressed Air Connection |
N / A |
Compressed Air Volume |
N / A |
Inlet Pipe Connection |
3/8" M.N.P.T.
3/8" M.B.S.P.T. (CE and Australia Only) |
Electric |
Voltage Available |
200-416v 1,3ø 2,3,4w
50/60 Hz
|
Approximate Net Weight |
285 lb
|
129.27 kg
|
Approximate Shipping Weight |
310 lb
|
140.61 kg
|
Airflow (60 Hz) |
360 cfm
|
10.19 cmm
|
Airflow (50 Hz) |
300 cfm
|
8.49 cmm
|
Exhaust Connection (Diameter) |
6"
|
15.24 cm
|
Compressed Air Connection |
N / A |
Compressed Air Volume |
N / A |
Oven Size |
|
kW
|
Btu/hr
|
kcal/hr
|
|
7.9
|
26,962
|
6,794
|
|
8.3
|
28,327
|
7,138
|
|
9.0
|
30,716
|
7,740
|
|
11.3
|
38,566
|
9,719
|
|
12.4
|
42,320
|
10,665
|
|
12.5
|
42,661
|
10,751
|
|
13.5
|
46,074
|
11,611
|
|
Steam |
Voltage Available |
120-240v 1ø 2w 50/60 Hz
|
Approximate Net Weight |
305 lb
|
138.35 kg
|
Approximate Shipping Weight |
330 lb
|
149.69 kg
|
Airflow (60 Hz) |
360 cfm
|
10.19 cmm
|
Airflow (50 Hz) |
300 cfm
|
8.49 cmm
|
Steam Consumption |
63 lb/hr
|
28.58 kg/hr
|
Operating Steam Pressure |
150 psi max
|
10.34 bar
|
Exhaust Connection (Diameter) |
6"
|
15.24 cm
|
Compressed Air Connection |
N / A |
Compressed Air Volume |
N / A |
Boiler Horsepower
(Normal Load) |
1.75 Bhp
|
Supply Connection |
1/2" F.N.P.T. |
Return Connection |
1/2" M.N.P.T. |
Electrical Specifications |
| |
Gas Models |
Volt / Hz / Phase |
Amps |
| |
Non-Rev |
Rev |
120 / 60 / 1 |
10.3
|
10.3
|
200 / 60 / 1 |
8.7
|
8.7
|
208 / 60 / 1 |
8.4
|
8.4
|
220 / 60 / 1 |
8.1
|
8.1
|
240 / 60 / 1 |
7.7
|
7.7
|
200 / 50 / 1 |
8.8
|
8.8
|
220 / 50 / 1 |
8.1
|
8.1
|
230 / 50 / 1 |
7.4
|
7.4
|
240 / 50 / 1 |
7.0
|
7.0
|
Electric Models |
Volt / Hz / Phase / kW |
Amps |
| |
Non-Rev |
Rev |
|
200 / 60 / 1 / 12.5
|
68.4
|
68.4
|
|
208 / 60 / 1 / 7.9
|
43.8
|
43.8
|
|
208 / 60 / 1 / 13.5
|
70.7
|
70.7
|
|
240 / 60 / 1 / 9.0
|
42.7
|
42.7
|
|
240 / 60 / 1 / 13.5
|
61.5
|
61.5
|
|
208 / 60 / 3 / 13.5
|
43.3
|
43.3
|
|
220 / 60 / 3 / 11.3
|
35.3
|
35.3
|
|
240 / 60 / 3 / 13.5
|
37.7
|
37.7
|
|
380 / 60 / 3 / 11.3
|
22.8
|
22.8
|
|
200 / 50 / 1 / 12.5
|
67.7
|
67.7
|
|
230 / 50 / 1 / 8.3
|
41.3
|
41.3
|
|
230 / 50 / 1 / 12.4
|
59.1
|
59.1
|
|
230 / 50 / 3 / 12.4
|
36.5
|
36.5
|
|
380 / 50 / 3 / 11.3
|
22.6
|
22.6
|
|
400 / 50 / 3 / 12.4
|
23.1
|
23.1
|
|
416 / 50 / 3 / 13.5
|
23.7
|
23.7
|
Steam Models |
Volt / Hz
/ Phase |
Amps |
| |
Non-Rev |
Rev
|
|
120 / 60 / 1
|
9.3
|
9.3
|
|
240 / 60 / 1
|
5.1
|
5.1
|
|
208 / 50 / 1
|
6.0
|
6.0
|
|
220 / 50 / 1
|
5.5
|
5.5
|
|
230 / 50 / 1
|
5.4
|
5.4
|
|
|
|